Investigation Report
Sikorsky S-92A Severe Vibration and Tail Rotor Pivot Bearing Separation
Read at AAIBOpens the publisher’s page on gov.uk
Summary
Investigation of severe vibration aboard Sikorsky S-92A G-CHCK, followed by a successful run-on landing. Tail rotor pivot bearing separation was probably preceded by retainer disbonding. The report examines bearing inspection access and instructions, revised inspection intervals, and a flight recorder configuration mismatch addressed through labelling and post-installation testing.