Summary
Investigation of a Super Puma takeoff rejection at Aberdeen Airport following rotor spindle fatigue failure. Metallurgical examination, finite element modelling, fatigue tests and flight-load measurements examined assembly preload, wear and interference-fit stresses. The report describes revised spindle assembly arrangements and recommends reviewing options to extend helicopter health and usage monitoring into rotating systems.