Summary
An investigation describes a well-testing employee falling some 95 feet into the water during temporary flare-boom installation on Diamond Ocean Summit. A pedestal weld failed after personnel tested the boom by jumping. The report examines absent fall protection, crane support and the need for reliable automatic ignition to reduce access to the boom.