Investigation Report

Drill-Pipe Assembly Dropped During Well Abandonment

BSEEBureau of Safety and Environmental Enforcement

11-13-2021 16:20 G21801 GC 518 OTHER LIFTING Elevators

Read at BSEEOpens the document on bsee.gov

Summary

An investigation examines a drill-pipe assembly dropped during well abandonment operations at Green Canyon Block 518. Incorrect elevator inserts were installed without positive confirmation against the rental pipe data sheet. The assembly fell approximately one foot; no injuries were reported. Subsequent procedure changes introduced data-sheet verification for insert changes.

Topics

About This Record
Original title
11-13-2021 16:20 G21801 GC 518 OTHER LIFTING Elevators
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Dropped Objects
Activity
Lifting Operations, Well Abandonment
Equipment
Lifting Accessories
Control
Pre-Use Checks
Sector
Upstream Oil and Gas
Link
Checked , working