Investigation Report

Telescopic-Joint Seal Failure Released Synthetic-Base Mud During Drill-Pipe Withdrawal

BSEEBureau of Safety and Environmental Enforcement

06-20-2015 14:05 G16647 MC 772 Pollution - Spill

Read at BSEEOpens the document on bsee.gov

Summary

An investigation examines a 12-barrel synthetic-base mud discharge during drill-pipe withdrawal on Ensco 8500. The upper telescopic-joint seal failed, while its audible alarm remained inactive because air pressure stayed within operating range. Engaging the lower seal stopped the release; the reason for the upper seal failure remained unknown.

Topics

About This Record
Original title
06-20-2015 14:05 G16647 MC 772 Pollution - Spill
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Environmental Protection, Loss of Containment, Mechanical Failure
Activity
Drilling
Control
Alarm Management, Preventive Maintenance
Sector
Upstream Oil and Gas
Setting
Marine Waters, Offshore Installation
Link
Checked , working
Record
bsee-3426fed28e · added 2 October 2026