Summary

An investigation examines a facial and head injury during pipe tripping on Hercules 300. An air-hoist cable became entangled with a kelly hose safety clamp, loading an anchor post that broke. Findings identify the driller’s blind spot, absent cable-clearance checks and a generic job safety analysis that omitted critical hazards.

Topics

About This Record
Original title
12-16-2012 18:00 G33608 VR/342 LTA 1-3 days/Head Injury
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Human Factors, Line of Fire, Mechanical Failure
Activity
Drilling
Control
Job Safety Analysis, Safety Communication
Sector
Upstream Oil and Gas
Setting
Offshore Installation