Investigation Report

Nylon Sling Eye Fails During Coiled-Tubing Riser Lift

BSEEBureau of Safety and Environmental Enforcement

12-12-2014 09:00 00830 SS 229 A Required Evacuation / Other Lifting Device / Equipment Failure / Human Error

Read at BSEEOpens the document on bsee.gov

Summary

An investigation examines a nylon sling eye failure during crane lifting of a coiled-tubing riser at Ship Shoal 229 A, fracturing a worker’s wrist. Findings identify unsuitable rigging, poor sling condition, inadequate training and supervision, absent pre-use inspection, incomplete job safety analysis and unavailable rigging procedures.

Topics

About This Record
Original title
12-12-2014 09:00 00830 SS 229 A Required Evacuation / Other Lifting Device / Equipment Failure / Human Error
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Hand and Finger Injuries, Line of Fire, Mechanical Failure
Activity
Lifting Operations, Rigging
Equipment
Lifting Accessories
Control
Competence and Training, Job Safety Analysis, Operating and Work Procedures, Pre-Use Checks
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-a2e1c4da37 · added 2 October 2026