Investigation Report
Casing Dropped After Elevators Struck Derrick During Drilling
Read at BSEEOpens the document on bsee.gov
Summary
Investigation of a casing drop during drilling on the Nabors 202 rig. Single joint elevators struck the derrick A-frame and failed, releasing casing and displacing another joint. An employee tripped while moving away. Findings identify missing block-speed and overpull instructions and non-use of a crane to control the casing’s lower end.