Investigation Report
Gas Release Following Sand Damage to Well Equipment
Read at BSEEOpens the document on bsee.gov
Summary
Investigation of sand damage and a subsequent gas release from well A-15 at HI-A571. Sand damaged the choke and pressure-relief discharge piping, blocked pressure-sensing lines and impeded safety-valve closure. Manual wing-valve closure stopped the leak. Investigators also found a gas-detection shutdown relay bypassed and identified inadequate monitoring for continued sand production.