Investigation Report

Broken Pipe Stop Arm Struck Worker During Well Abandonment

BSEEBureau of Safety and Environmental Enforcement

09-25-2014 13:50 G01026 SS 241 Required Evacuation / Other Injury / Equipment Failure

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a pipe stop arm failure during well abandonment on the SS 241 platform. A broken section fell 24 feet and struck a worker’s right arm. Metallurgical analysis identified incomplete weld penetration and lack of fusion; design documentation omitted complete joint penetration requirements. The worker returned to full duty the following day.

Topics

About This Record
Original title
09-25-2014 13:50 G01026 SS 241 Required Evacuation / Other Injury / Equipment Failure
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Dropped Objects, Mechanical Failure, Structural and Asset Integrity
Activity
Well Abandonment, Well Intervention
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-ec902d85cb · added 2 October 2026