Investigation Report
Broken Pipe Stop Arm Struck Worker During Well Abandonment
Read at BSEEOpens the document on bsee.gov
Summary
Investigation of a pipe stop arm failure during well abandonment on the SS 241 platform. A broken section fell 24 feet and struck a worker’s right arm. Metallurgical analysis identified incomplete weld penetration and lack of fusion; design documentation omitted complete joint penetration requirements. The worker returned to full duty the following day.