Safety Alert

Safety Alert 142 - Pollution Because of Failure of Level Safety High Sensor and Level Controller

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 142

Safety Alert 142 - Pollution Because of Failure of Level Safety High Sensor and Level Controller

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

An oil tank’s level controller and high-level safety sensor failed, allowing oil into a low-pressure flare scrubber. Two barrels were blown overboard when the compressor shut down and routinely vented gas. Paraffin blocked the float cage, and the controller float was set too high. Planned measures include float repositioning and periodic solvent injection.