Safety Alert

Safety Alert 208 - Loss of Well Control

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 208

Safety Alert 208 - Loss of Well Control

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

An MMS alert describes a kick during gravel-pack wash-over and a release through a mud-pump pressure safety valve during bull-heading. Investigators identified possible shear-pin deformation following repeated near-set-pressure exposures. Recommendations address visual inspection after such exposures, maintenance to manufacturers’ recommendations and routing valve discharges to a safe location.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 208
Date
19 December 2002 (added from another catalogue record)
Topic
Loss of Containment, Mechanical Failure, Well Control
Activity
Inspection and Maintenance, Well Intervention
Equipment
Valve
Control
Pressure Relief
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-safety-alert-208 · added 2 September 2026