Safety Alert

Safety Alert 214 - Flash Fire and Explosion from Inadequately Vented Production Vessel

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 214

Safety Alert 214 - Flash Fire and Explosion from Inadequately Vented Production Vessel

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

A confined-space sampling operation in a low-pressure separator resulted in a flash explosion, injuring four workers and blowing one off the platform into the water. The alert identifies inadequate ventilation and incomplete gas-detector deployment, and recommends procedural confirmation, hatchway hazard awareness, flotation-device readiness and review of guard barriers.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 214
Date
15 July 2003 (added from another catalogue record)
Topic
Confined Space Hazards, Drowning, Explosion, Falls from Height, Fire
Activity
Confined Space Entry
Equipment
Gas Detector, Pressure Vessel
Control
Fall Prevention, Atmospheric Gas Testing, Operational Supervision, Ventilation
Sector
Upstream Oil and Gas
Link
Checked , working