Safety Alert

Safety Alert 298 - Electric Line Failure from Corrosion Results in Injury

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 298

Safety Alert 298 - Electric Line Failure from Corrosion Results in Injury

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

During temporary well abandonment, a corroded electric line parted while positioning a bridge plug assembly, which fell and struck a worker’s foot. The alert examines corrosion-related overload fractures, an unassessed lifting hazard and missing maintenance records, recommending wireline procedures, inspection and maintenance records, and effective implementation of job safety analysis controls.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 298
Date
30 December 2011
Topic
Corrosion, Dropped Objects
Activity
Lifting Operations, Well Abandonment
Control
Job Safety Analysis, Operating and Work Procedures, Preventive Maintenance
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-safety-alert-298 · added 2 September 2026