Safety Alert

EI 158 Fatality Failure to Use Safety

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 476

EI 158 Fatality Failure to Use Safety

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

An offshore worker died when surface casing failed during pressure testing supplied by a high-pressure well. The explosion involved pressure release without signs of ignition. BSEE identifies omitted pressure safeguards and deficiencies in planning and change management, and recommends operators consider equipment compatibility checks, gauge training and improved hazard assessment.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 476
Date
21 November 2023
Topic
Explosion, Pressure Systems, Well Integrity
Activity
Pressure Testing
Equipment
Valve
Control
Job Safety Analysis, Management of Change, Pressure Relief, Risk Assessment
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-safety-alert-476 · added 2 September 2026

Report a problem with this record