Summary

Six pipe stands fell from a drilling rig fingerboard during cement-line pressure testing, with nobody on the rig floor. Investigators identified adverse weather and poor fingerboard design as main causes. The alert describes an enhanced locking arrangement and recommends considering bolt inspections, improved securing mechanisms and Red Zone management where required.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Date
25 January 2024 (taken from the file name)
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance
Control
Exclusion Zones, Positive Retention and Reliable Securing
Sector
Upstream Oil and Gas