Digest

Do your shutoff systems actually work? — Process Safety Beacon, March 2008

CCPSCenter for Chemical Process Safety, AIChEProcess Safety Beacon March 2008

Do your shutoff systems actually work? — Process Safety Beacon, March 2008

Read at CCPSOpens the publisher’s page on ccps.aiche.org

Summary

A chemical feed tank overflowed despite its high-level shutoff interlock because liquid downstream of the closed valve could still fill the tank. The bulletin explains the importance of valve location and switch height, and recommends testing complete safety systems rather than individual components.

Topics

About This Record
Publisher
Center for Chemical Process Safety, AIChE
Type
Digest
Reference
Process Safety Beacon March 2008
Date
March 2008 (taken from the file name)
Topic
Functional Safety, Loss of Containment
Activity
Fluid Transfer
Equipment
Pumps, Storage Tanks, Valve
Control
Functional Testing
Sector
Downstream and Process Industries
Link
Checked , could not be checked
Record
ccps-beacon-2008-03 · added 1 September 2026