Investigation Report

Williams Olefins Plant Explosion and Fire

CSBU.S. Chemical Safety and Hazard Investigation Board

Williams Olefins Plant Explosion and Fire

Read at CSBOpens the publisher’s page on csb.gov

Summary

CSB case study examines the fatal Williams Geismar reboiler rupture, BLEVE and fire. It analyses likely liquid thermal expansion in standby equipment lacking effective pressure relief, alongside shortcomings in change management, hazard analysis and operating procedures. Metallurgical testing, finite element analysis and process modelling inform the failure assessment and recommendations.

Topics

About This Record
Publisher
U.S. Chemical Safety and Hazard Investigation Board
Type
Investigation Report
Date
19 October 2016
Topic
Explosion, Fire, Hydrocarbon Release, Pressure Systems, Process Safety
Equipment
Pressure Vessel, Valve
Control
Management of Change, Operating and Work Procedures, Pressure Relief, Risk Assessment
Sector
Downstream and Process Industries
Link
Checked , working
Record
csb-williams-olefins-plant-explosion-and-fire · added 2 September 2026

Report a problem with this record