Safety Alert

Hooped ladders and the use of personal fall-arrest systems

HSEUK Health and Safety ExecutiveCCID1-2012

Hooped ladders and the use of personal fall-arrest systems

Read at HSEOpens the publisher’s page on hse.gov.uk

Summary

This HSE alert examines limitations of fixed hooped ladders and their interaction with personal fall-arrest systems. Hoops may compromise arrest equipment and users may strike the cage during a fall. Dutyholders are advised to review risk assessments and consider additional protection or alternative access; blanket hoop removal is not recommended.

Topics

About This Record
Publisher
UK Health and Safety Executive
Type
Safety Alert
Reference
CCID1-2012
Date
10 July 2012 (added from another catalogue record)
Topic
Falls from Height
Activity
Working at Height
Equipment
Fall Protection Equipment, Ladder
Control
Risk Assessment
Link
Checked , working
Record
hse-ccid1-2012 · added 2 September 2026