Safety Alert

Failure of a road tanker pressure/vacuum relief valve

HSEUK Health and Safety ExecutiveCEMHD2-2020

Failure of a road tanker pressure/vacuum relief valve

Read at HSEOpens the publisher’s page on hse.gov.uk

Summary

HSE safety alert describes a modified road-tanker relief valve that stuck open, releasing nitric acid vapour without injuries or property damage. A welded nut obstructed the valve stem. It calls for visual checks for unauthorised modifications, manufacturer-guided servicing and verification of both pressure and vacuum protection functions.

Topics

About This Record
Publisher
UK Health and Safety Executive
Type
Safety Alert
Reference
CEMHD2-2020
Date
February 2021
Topic
Hazardous Substances, Loss of Containment, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance, Pressure Testing, Vehicles and Driving
Equipment
Valve
Control
Competence and Training, Functional Testing, Pressure Relief, Preventive Maintenance
Link
Checked , working
Record
hse-cemhd2-2020 · added 2 September 2026