Summary
HSE alert following a fatal frozen-food-store ceiling failure involving insulation panels secured with engineering-grade plastic bolts. Tests identified bolt fatigue and corrosion, while some failed fixings showed no obvious signs. Recommendations address fragile ceilings, access restrictions, inspection from underneath, loading guidance and independently supported walkways where frequent access is required.