Safety Alert

Near Miss – Sticking BOP Control Valve

IADCInternational Association of Drilling ContractorsIADC Alert 01-11

Near Miss – Sticking BOP Control Valve

Read at IADCOpens the publisher’s page on iadc.org

Summary

An alert describes uncommanded shear-ram closure during remote BOP function testing, which squashed but did not shear a drill-pipe joint. A crewman noticed the closed indicator before the test string was lifted. It also mentions another recent event in which lifting with closed shear rams parted a string, dropping the remainder.

Topics

About This Record
Publisher
International Association of Drilling Contractors
Type
Safety Alert
Reference
IADC Alert 01-11
Date
9 April 2001
Topic
Dropped Objects, Mechanical Failure
Activity
Drilling, Inspection and Maintenance
Equipment
Blowout Preventer, Valve
Control
Functional Testing
Sector
Upstream Oil and Gas
Link
Checked , working
Record
iadc-alert-01-11 · added 3 September 2026

Report a problem with this record