Summary
During BOP retrieval through the splash zone, reduced resistance and rig movement produced a pendulum effect. The riser struck the stored gooseneck ring, which fell onto the flex joint. The BOP was then raised and secured; damage to the storage dogs and their locking mechanism caused downtime.
Classifications: Dropped objects; falling objects; DROPS.
Classifications: Structural and asset integrity; asset integrity; structural integrity.
Classifications: Lifting operations; load lifting; hoisting.
Classifications: Blowout preventer; BOP; blow-out preventer.
Classifications: Upstream oil and gas; oil and gas extraction; upstream petroleum.