Safety Flash

Commissioning and verification of newly installed modified diving system equipment

IMCAInternational Marine Contractors AssociationIMCA SF 01/00

Commissioning and verification of newly installed modified diving system equipment

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A serious near-miss involved unintended diving bell recovery before its door was secured. Modified winch systems had malfunctioning primary and emergency components, with no documented acceptance-test protocol. Recommendations address change assessment, defined responsibilities, subsystem schematics, operating procedures and competent, supervised acceptance testing with retained records.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 01/00
Date
1 January 2000
Topic
Mechanical Failure
Activity
Diving Operations
Equipment
Diving Bell, Winch
Control
Competence and Training, Functional Testing, Management of Change, Operating and Work Procedures
Link
Checked , working
Record
imca-sf-01-00-commissioning-and-verification-of-newly-installed-modified-diving-system-equipment · added 1 September 2026