Near-miss during connector pressure tests

IMCAInternational Marine Contractors AssociationIMCA SF 01/04

Near-miss during connector pressure tests

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diver’s hydraulic fitting blew off during removal following a successful connector pressure test, despite a zero surface pressure reading. Trapped annulus pressure was reported; poppet failure was considered the most likely cause. The company proposed a tee and needle-valve check to confirm ambient pressure before hose disconnection.