Summary

An air diver disconnecting an FPSO riser was dragged down to -70fsw after a lateral pull caused the riser to drop and part its webbing slings. His umbilical fouled on the crane wire. The flash addresses umbilical slack management, underwater sling selection, load calculations and separation of divers from planned load movements.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 01/10
Date
9 February 2010
Topic
Dropped Objects, Entanglement, Line of Fire
Activity
Diving Operations, Lifting Operations, Rigging
Equipment
Diver Umbilical, Lifting Accessories, Wire Rope
Control
Lifting Plan, Risk Assessment
Sector
Upstream Oil and Gas
Setting
Subsea