Summary
A strop eye failed while two 400 kg buoyancy blocks were recovered from the seabed, allowing one to rise uncontrolled. Nobody was injured and no damage occurred. The alloy sleeve had corroded after about 11 months underwater. Suggested precautions address prolonged submergence, recovery checks and visual inspection before use.
Classifications: Corrosion; corrosion damage.
Classifications: Mechanical failure; equipment failure.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Rigging; slinging.
Classifications: Lifting accessories; lifting gear; rigging gear.
Classifications: Wire rope; steel wire rope.
Classifications: Pre-use checks; pre-use inspection.
Classifications: Subsea; underwater worksite.
Summary
An alloy-swaged rigging eye failed after prolonged underwater exposure caused corrosion of its sleeve.