Safety Flash
LTI: Finger injury during work with rotating machinery
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An electrician suffered serious finger injuries when a cotton glove became entangled in a pillar drill while enlarging a cable shoe hole without properly securing the workpiece. The flash identifies absent risk assessment and toolbox discussion, ignored signage and rushing, and advises against gloves and loose clothing around rotating machinery.