Safety Flash

Umbilical management – near miss

IMCAInternational Marine Contractors AssociationIMCA SF 02/23

Umbilical management – near miss

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diver’s umbilical became trapped when a pipeline rolled during crane-assisted removal of sleeper supports beneath a repair spool. The diver freed it and was unharmed. The flash identifies missing removal procedures, unrecognised umbilical hazards and absent change management, recommending a removal procedure and crew review.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 02/23
Date
11 January 2023
Topic
Human Factors, Line of Fire
Activity
Diving Operations, Lifting Operations
Equipment
Diver Umbilical, Process Pipework and Pipelines
Control
Management of Change, Operating and Work Procedures, Safety Communication, Stop-Work Authority
Setting
Subsea
Link
Checked , working
Record
imca-sf-02-23-umbilical-management-near-miss · added 1 September 2026