Safety Flash

Fatality and serious injuries during heavy lift operation

IMCAInternational Marine Contractors AssociationIMCA SF 03/03

Fatality and serious injuries during heavy lift operation

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A hydraulic lifting system collapsed near completion of a 300 tonne alternator lift, killing one man and injuring nine others. The cause was unknown. This follow-up flash examines possible transverse instability and recommends competent stability review, calculated alignment tolerances, communication through method statements and monitoring of cylinder alignment.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 03/03
Date
1 April 2003
Topic
Mechanical Failure, Structural and Asset Integrity
Activity
Lifting Operations
Control
Competence and Training, Lifting Plan, Operating and Work Procedures, Safety Communication