A hyperbaric extinguisher’s safety valve assembly blew off during six-monthly functional checks at a shore-base workshop, without injury. A faulty first-stage regulator and non-functioning burst disc were identified. Actions included phasing out twin-cylinder extinguishers, annual burst-disc replacement and improved equipment traceability.