Safety Flash

Near miss: Unidentified differential pressure led to diver’s umbilical getting trapped

IMCAInternational Marine Contractors AssociationIMCA SF 03/17

Near miss: Unidentified differential pressure led to diver’s umbilical getting trapped

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An inshore diving near miss involved an umbilical drawn into a gravity-fed seawater intake and trapped by automated cleaning equipment. A second diver cut the line, enabling both divers to surface uninjured. Findings address undisclosed automation, inadequate isolation and risk review, with corrective actions covering lockout verification and dive-tender repositioning.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 03/17
Date
13 February 2017
Topic
Entanglement, Risk Management
Activity
Diving Operations
Equipment
Diver Umbilical
Control
Evacuation, Escape and Rescue, Lockout and Tagout, Risk Assessment, Safety Communication