Safety Flash

Near-miss during subsea cutting operations

IMCAInternational Marine Contractors AssociationIMCA SF 04/12

Near-miss during subsea cutting operations

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A flashback during subsea gas flame cutting with a PVL torch ruptured an oxygen hose underwater and on deck, causing a small fire without injuries. Investigation identified missing flashback arrestors, incorrect bottle-change procedures and an improperly closed torch valve. Changes included arrestors, non-return valves, gas quads and revised instructions.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 04/12
Date
30 April 2012
Topic
Fire, Pressure Systems
Activity
Diving Operations, Hot Work
Equipment
Gas Cylinder, Hose, Valve
Control
Operating and Work Procedures
Setting
Subsea
Link
Checked , working
Record
imca-sf-04-12-near-miss-during-subsea-cutting-operations · added 1 September 2026