Safety Flash

Burns caused by release of steam and boiling water from overheated pump

IMCAInternational Marine Contractors AssociationIMCA SF 05/06

Burns caused by release of steam and boiling water from overheated pump

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During filling and pigging, a centrifugal pump overheated and water flashed to steam, raising pressure and violently separating its suction hose from the fitting. A nearby worker suffered second-degree leg burns. The company recommended evaluating procedures and piping systems for high-volume centrifugal pumps to ensure fitness for purpose.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/06
Date
30 April 2006
Topic
Loss of Containment, Mechanical Failure, Pressure Systems
Activity
Fluid Transfer
Equipment
Hose, Pumps
Control
Operating and Work Procedures
Link
Checked , working
Record
imca-sf-05-06-burns-caused-by-release-of-steam-and-boiling-water-from-overheated-pump · added 1 September 2026