Safety Flash

LTI: Carbon Monoxide (CO) poisoning during Oxy-Acetylene brazing

IMCAInternational Marine Contractors AssociationIMCA SF 05/23

LTI: Carbon Monoxide (CO) poisoning during Oxy-Acetylene brazing

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A crew member suffered carbon monoxide poisoning while repairing a refrigeration valve using oxy-acetylene brazing. The flash identifies incomplete risk assessment, omitted exhaust ventilation and inconsistent mask requirements. Lessons address ventilation, exposure duration, air testing, conditional respirator use with personal CO monitoring, and further welding-hazard training.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/23
Date
16 February 2023
Topic
Hazardous Substances, Respiratory Hazards
Activity
Hot Work, Inspection and Maintenance
Equipment
Personal Protective Equipment, Respirator
Control
Competence and Training, Occupational Exposure Monitoring, Risk Assessment, Ventilation
Sector
Marine Industry
Link
Checked , working
Record
imca-sf-05-23-lti-carbon-monoxide-co-poisoning-during-oxy-acetylene-brazing · added 1 September 2026