Safety Flash

First aid injury: Thermos cup exploded after being in hyperbaric environment

IMCAInternational Marine Contractors AssociationIMCA SF 07/14

First aid injury: Thermos cup exploded after being in hyperbaric environment

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A thermal cup returned from saturation through a medical airlock separated violently from its plastic base at surface pressure, causing minor bruising to an assistant life support technician. The flash records the diver’s assumption about pressure differential and recommends drilling such vessels or prohibiting non-venting thermal vessels in saturation chambers.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 07/14
Date
13 May 2014
Topic
Explosion, Pressure Systems
Activity
Saturation Diving
Control
Pressure Relief, Safety Communication
Link
Checked , working
Record
imca-sf-07-14-first-aid-injury-thermos-cup-exploded-after-being-in-hyperbaric-environment · added 1 September 2026