Safety Flash

Partial parting of a bell main lift wire

IMCAInternational Marine Contractors AssociationIMCA SF 08/08

Partial parting of a bell main lift wire

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diving bell’s main lift wire was found damaged during recovery following partial parting. Internal corrosion had reduced core wire sizes by up to 50%, despite no visible external damage. The flash examines lubricant loss, undetected deterioration and possible sheave and loading effects, urging members to consider reviewing wire-rope maintenance and testing policies.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 08/08
Date
24 April 2008
Topic
Corrosion, Mechanical Failure
Activity
Diving Operations, Inspection and Maintenance, Lifting Operations
Equipment
Diving Bell, Wire Rope
Control
Preventive Maintenance
Link
Checked , working
Record
imca-sf-08-08-partial-parting-of-a-bell-main-lift-wire · added 1 September 2026

Report a problem with this record