Summary

A gangway struck a hyperbaric chamber fitting during raising, causing uncontrolled decompression of a man-way trunk and adjacent entry lock. Four divers were in saturation; no injuries were reported. Initial findings identified an unprotected fitting and door misalignment. Recommendations address impact protection, door alignment and management of proposed modifications.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 09/04
Date
1 October 2004
Topic
Pressure Systems, Structural and Asset Integrity
Activity
Marine Operations, Saturation Diving
Equipment
Gangway, Pressure Vessel, Valve
Control
Management of Change