Safety Flash

Poor storage leading to failure and disintegration of cutting discs

IMCAInternational Marine Contractors AssociationIMCA SF 10/15

Poor storage leading to failure and disintegration of cutting discs

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Several incidents involved cutting discs disintegrating during use. Manufacturer investigation identified inappropriate storage as the most likely root cause, with dampness degrading the resin binding bonded abrasives. The flash encourages reviewing disc storage and describes dry, frost-free conditions, protection and support to prevent damage and distortion.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 10/15
Date
16 July 2015
Topic
Mechanical Failure
Equipment
Grinding Equipment
Link
Checked , working
Record
imca-sf-10-15-poor-storage-leading-to-failure-and-disintegration-of-cutting-discs · added 1 September 2026

Report a problem with this record