Safety Flash

Injury sustained while operating steel lifting magnet

IMCAInternational Marine Contractors AssociationIMCA SF 14/25

Injury sustained while operating steel lifting magnet

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A crew member suffered a cheek cut requiring fifteen stitches when a steel lifting magnet’s spring-loaded lever recoiled during adjustment. The flash also describes an earlier chin injury involving the same magnet. It examines lever accessibility, maintenance gaps and faded warnings, recommending regular inspection, fault reporting and equipment suitability evaluation.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 14/25
Date
14 August 2025
Topic
Human Factors, Line of Fire
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Magnetic Lifter
Control
Safety Communication
Link
Checked , working
Record
imca-sf-14-25-injury-sustained-while-operating-steel-lifting-magnet · added 1 September 2026