Safety Flash

Pallet lifter failure

IMCAInternational Marine Contractors AssociationIMCA SF 16/08

Pallet lifter failure

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A pallet lifter failed during quayside cargo transfer to a vessel, dropping a crane motor without injury. Corrosion had weakened the frame despite previous inspection. The flash examines conflicting load-weight information, missed deterioration and delayed reporting, recommending thorough equipment checks, accurate weight verification and immediate reporting of lifting-equipment failures.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 16/08
Date
30 October 2008
Topic
Corrosion, Dropped Objects, Incident Investigation, Mechanical Failure
Activity
Cargo Transfer, Inspection and Maintenance, Lifting Operations
Equipment
Lifting Accessories
Control
Lifting Plan, Pre-Use Checks
Sector
Marine Industry
Setting
Port and Quayside
Link
Checked , working
Record
imca-sf-16-08-pallet-lifter-failure · added 1 September 2026