Safety Flash
LTI: Foot injury after standing on rotating winch drum
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An able seaman sustained a fractured foot and severe abrasions after standing on a rotating tugger winch drum during wire re-spooling. His boots limited injury severity. The flash highlights unrecognised winch hazards, inadequate risk assessment and absent intervention, with actions focused on hazard identification, assessment reviews and stopping unsafe work.