Safety Flash

Near miss: Dropped magnet during dry docking

IMCAInternational Marine Contractors AssociationIMCA SF 17/19

Near miss: Dropped magnet during dry docking

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During dry docking, a magnet securing fire protection fell 32 m from scaffolding while the protection was adjusted during hot work. No injuries or damage occurred. The flash identifies absent secondary retention and barriers below the worksite, and calls for identifying equipment used at height and suitable dropped-object controls.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 17/19
Date
16 July 2019
Topic
Dropped Objects, Line of Fire
Activity
Hot Work, Working at Height
Equipment
Scaffold
Control
Exclusion Zones, Fire Protection, Positive Retention and Reliable Securing
Sector
Marine Industry
Link
Checked , working
Record
imca-sf-17-19-near-miss-dropped-magnet-during-dry-docking · added 1 September 2026

Report a problem with this record