Summary

A Chinese Finger connector failed during reeving of a crane’s auxiliary hoist, dropping the hoist wire into a cargo hold and the messenger wire onto the main deck. The account identifies a sharp, untapered wire end, point loading and insufficient tension resistance. Nobody was injured.