Safety Flash

Stored pressure near-miss: Buckle detector expelled from pipe during recovery

IMCAInternational Marine Contractors AssociationIMCA SF 18/16

Stored pressure near-miss: Buckle detector expelled from pipe during recovery

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A buckle detector weighing approximately 25 kg was expelled from a pressurised pipeline during retrieval, landing approximately 2 m away and coming close to two crew members. The flash identifies unassessed back pressure and inadequate task planning, and describes stopping operations, exclusion barriers, sling retention and consideration of revised risk assessments.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 18/16
Date
4 July 2016
Topic
Line of Fire, Pressure Systems, Risk Management
Equipment
Process Pipework and Pipelines
Control
Exclusion Zones, Positive Retention and Reliable Securing, Risk Assessment, Stop-Work Authority