COBRA bailout system – guidance note
COBRA bailout system – guidance note
- IMCA
- Safety Flash
- IMCA SF 21/21
- CorrosionDivingInspection and MaintenancePressure Systems
- CorrosionPressure systems
- Diving operationsInspection and maintenance
- Gas cylinder
- Pre-use checks
Summary
This safety flash summarises JFD’s investigation of lacquer blistering and excessive aluminium-neck corrosion in COBRA’s 2L composite cylinders. It distinguishes manufacturer assurances about lacquer defects from unresolved batch concerns, and advises external-condition checks whenever sets leave the dive system, with replacement and IDEST inspection before re-use where condition is questionable.
Classifications: Corrosion; corrosion damage.
Classifications: Pressure systems; stored pressure; pressurised systems; pressurized systems.
Classifications: Diving operations; diving; commercial diving.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Gas cylinder; compressed gas bottle; gas cylinders.
Classifications: Pre-use checks; pre-use inspection.
Summary
JFD has issued a COBRA guidance note relating to concerns regarding the suitability of the 2L composite cylinders contained within the set. This note highlights to users, those reported concerns and the follow-on investigation that has been undertaken to demonstrate suitability of the composite cylinders for the application in COBRA.
IMCA SF 21/21. Themes: corrosion, diving, inspection and maintenance, pressure systems.