Safety Flash

BSEE: Anchor-handling causes damage to subsea equipment and triggers gas release

IMCAInternational Marine Contractors AssociationIMCA SF 23/25

BSEE: Anchor-handling causes damage to subsea equipment and triggers gas release

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An anchor wire snagged a subsea well during recovery by a dive support vessel, subsequently detaching an annulus valve and releasing gas. The flash summarises BSEE findings on inadequate planning, coordination and emergency preparation, with recommendations for consideration covering readiness checks, change management, communication and current-aware anchor-handling plans.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 23/25
Date
18 December 2025
Topic
Hydrocarbon Release, Loss of Station Keeping
Activity
Anchor Handling
Equipment
Valve, Wire Rope
Control
Emergency Response, Management of Change, Risk Assessment, Simultaneous Operations Coordination
Sector
Marine Industry, Upstream Oil and Gas
Setting
Subsea
Link
Checked , working
Record
imca-sf-23-25-bsee-anchor-handling-causes-damage-to-subsea-equipment-and-triggers-gas-release · added 1 September 2026

Report a problem with this record