Safety Flash

High potential near miss: tensioner pad dropped to under deck carousel

IMCAInternational Marine Contractors AssociationIMCA SF 26/18

High potential near miss: tensioner pad dropped to under deck carousel

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During umbilical trans-spooling, a retaining bolt sheared and a 1.5 kg tensioner pad fell 11 m, striking the umbilical before bouncing near a supervisor. The flash identifies deferred bolt replacement, omitted inspection and torque checks, and absent risk assessment. Actions address bolt grade, corrective work completion and assessment before work.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 26/18
Date
3 December 2018
Topic
Dropped Objects, Line of Fire, Mechanical Failure, Risk Management
Activity
Inspection and Maintenance
Control
Positive Retention and Reliable Securing, Risk Assessment
Link
Checked , working
Record
imca-sf-26-18-high-potential-near-miss-tensioner-pad-dropped-to-under-deck-carousel · added 1 September 2026