Safety Flash

Failure of proportional valve in saturation chamber control

IMCAInternational Marine Contractors AssociationIMCA SF 27/23

Failure of proportional valve in saturation chamber control

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A proportional valve feedback fault interrupted saturation diving, without injury or equipment damage. Automatic safeguards isolated the line and transferred control to a manual valve. Unauthorised dismantling obscured the origin of potentiometer damage; debris was also found. Lessons address manufacturer-led maintenance, critical spares, training and testing before diving resumes.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 27/23
Date
27 November 2023
Topic
Functional Safety, Incident Investigation, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance, Saturation Diving
Equipment
Pressure Vessel, Valve
Control
Competence and Training, Energy and Process Isolation, Operating and Work Procedures, Preventive Maintenance
Link
Checked , working
Record
imca-sf-27-23-failure-of-proportional-valve-in-saturation-chamber-control · added 1 September 2026