Safety Flash

Offshore crane safety systems

IMCAInternational Marine Contractors AssociationIMCA SF 34/16

Offshore crane safety systems

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This flash summarises two crane boom failures involving ineffective upper hoist limits. One involved a missing pneumatic valve blanking plug and a hydraulic pump actuator fault; the other involved a defeated operational limit and incorrectly set ultimate limit. It recommends robust inspection and functional testing against manufacturers’ specified boom angles.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 34/16
Date
16 December 2016
Topic
Functional Safety, Mechanical Failure